7.1 Characteristics VVX
Type
Electrical characteristics
Supply voltage
• Standard
• Voltage / Current output
0...10 V / 4...20 mA
Current consumption
• Frequency / Analogue
output
Electrical connection
Degree of protection
(EN 60529)
Connecting cable
(Accessory)
Process variables
Medium to measure
Temperature range:
- Medium
- Ambient
Nominal diameter
Inner diameter
Nominal pressure
Process connection
*1) Only with attached coupling

7.2 Materials in Contact With Media

Type
Component
Tube
Sensor
O-rings
Immersion sleeve
Bluff body
- 28 -
VVX15
VVX20
DN 15
Ø 13 mm
Ø 19 mm
G ¾ ISO 228
G1 - ISO 228
male
Quick-Fasten
VVX15 • VVX20 • VVX25
PPS
40 % glass fibre reinforced
-/-
-/-
VVX25
8...30 V
or 5 V
DC
12...24 V
< 15 mA
5-pin-plug M12x1 or 4-pin plug M12x1
*1
IP65
and IP67
Female connector M12x1 with cable
Water and aqueous solutions
-20...90 °C (non-freezing)
-20...70 °C
DN 20
DN 25
Ø 25 mm
PN 10
G 1¼ ISO
male •
228 male
Brass CW617N-DW
ETFE or PFA
EPDM
Brass CW724R
VVX32
±5%
DC
DC
*1
DN 32
Ø 32 mm
PN 16
G 1½-ISO
G 2-ISO 228
228 male
VVX32 • VVX40
Stainless steel
1.4581
Stainless steel
1.4571
PPS
40 % glass fibre reinforced
© SIKA • Ba_VVX • 01/2023
VVX
VVX40
DN 40
Ø 40 mm
male