Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Commissioning; Requirements On The Installation Location - DÜPERTHAL CLASSIC line90 Betriebsanleitung

Sicherheitsschränke
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13

Installation and commissioning

Requirements on the installation location

6

Installation and commissioning

Install the safety storage cabinet so that the annual maintenance activities can be carried out without restric-
tion.

6.1 Requirements on the installation location

The safety storage cabinet is approved for installation in a building.
Fig. 14: Requirements on the installation location
Consider the following in relation to the installation location:
The surface must be able to bear the weight of the safety storage cabinet when fully loaded.
n
The surface must be horizontal in order to guarantee problem-free functioning of the safety storage cabinet.
n
The load-bearing capacity and stability of the surface must be assured both in normal situations and in the event
n
of a fire.
Do not install the safety storage cabinet near sources of heat.
n
Protect the safety storage cabinet against moisture.
n
At a relative humidity of >70 % use in closed and heated buildings is permissible for a few weeks each
year.
The operating temperature must be between -5°C and +40°C.
n
CLASSIC line, COMPACT line
97

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Compact line 90

Inhaltsverzeichnis