Safety notes

• Before and during use make sure that the thermostat is
functioning correctly. Children and adults with reduced
sensory capabilities should not use the product
unsupervised.
• Installation is only possible in frost-free rooms.
• When the domestic water system is drained, the thermostats
must be drained separately since non-return valves are
installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
• Voltage supply:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (1 - 11 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape
• Start / stop water flow:
• Automatically stop water flow:
(20 - 45cm adjustable)
• Type of fitting protection:
Thermal disinfection possible.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Installation
, see fold-out page I.
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Battery discharged
(indicator lamp lights up continuously)
• Plug-in connector without contact
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filters in the union connection set blocked
Water temperature
• Thermostat not adjusted to local pressure
too high or too low
• Non-return valve defective
6V lithium battery type CR-P2
60 s
1 s
5cm
40cm
IP 69K
Reversed connection (hot on right - cold on left):.
Replace thermostatic cartridge 47 217, see fold-out page II,
Prod. no.: 47 657.
When using this thermostatic cartridge, the Cool Touch
function is no longer available.

Adjusting

Setting temperature see fold-out page I.
Adjusting hot water end stop
Attach red end stop to the desired maximum
temperature (35-43°C), see fold-out page I.
Operation,
see technical product information 99.0438.xxx.
Maintenance
, see fold-out page III - IV.
•Shut off hot and cold water supply.
•Inspect and clean all parts, replace if necessary and
lubricate with special grease.
•Readjustment is necessary after each maintenance
operation on the thermostatic cartridge (see
"Adjusting").
Replacement parts
see fold-out page II (* = special accessories)
,
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean filter
- Replace solenoid valve
- Replace battery
- Check plug-in connectors
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Adjust thermostatic cartridge
- Replace the non-return valve