Herunterladen Inhalt Inhalt Diese Seite drucken

Technische Daten; Funktion - BEMKO SES24WH Bedienungsanleitung

Pir -sensor
Vorschau ausblenden Andere Handbücher für SES24WH:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
CONNECTION
Warning! Danger of death through electric shock!
- must be installed by professional electrician
- disconnect power source
- cover or shied any adjacent live components
- check power supply is disconnected
Connect the power and the load according to the connection-wire diagram.
Fix the bottom on the selected position with the in ated screw.
Switch on the power and test it.
TEST
Slide the LUX switch
to SUN position (below is SUN). Slide the SENS switch to maximum (below is the
switch to ON position. (slide upwards)
Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work .If the sensor
receives the induction signal, the lamp will turn on. While there is no another induction signal any more, the load should stop working within 5sec and the lamp
would turn o .
Slide the LUX knob above on the minimum (moon). If the ambient light is more than 10LUX, the sensor would not work and the lamp stop working too. If the
ambient light is less than 3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor should stop working within 5sec.
NOTE: When testing in daylight, please turn LUX knob to
could not work! If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at
least.
MOST COMMON PROBLEMS AND SOLVING WAYS
The load does not work:
1) Please check if the connection of power source and load is correct.
2) Please check if the load is good.
3) Please check if the settings of working light correspond to ambient
light.
The sensitivity is poor:
1) Please check if there is any hindrance in front of the detector to a ect it
to receive the signals.

TECHNISCHE DATEN

Stromversorgung
Nennlast
Leistungsaufnahme
Standby-Leistung
Erfassungsreichweite
Umgebungslicht

FUNKTION

Helligkeitsschalter (night/24 hours): 2000LUX (TAG) – OFF (untere Position)
10LUX (NACHT) – ON (obere Position).
Emp ndlichkeitseinstellung (sens adjust): geringe Emp ndlichkeit – für kleine
Räume (ON - oben), hohe Emp ndlichkeit für große Räume (OFF- unten).
Einstellung der Zeitverzögerung (time-delay): 5s, 30s, 1min, 3 min, 5 min, 8 min.
(SUN) position, otherwise the sensor lamp
230V~ 50Hz
800W
400W
P
: <0.5W
on
P
: <0.5W
sb
3m/6m max (<24°C)
10LUX/2000LUX
2) Please check if the ambient temperature is too high.
3) Please check if the induction signal source is in the detection eld.
4) Please check if the installation height corresponds to the height required in
the instruction.
5) Please check if the moving orientation is correct.
The sensor can not shut o the load automatically:
1) Please check if there is continual signal in the detection eld.
2) Please check if the time delay is set to the maximum position.
DE
Erfassungsbereich
Zeitverzögerung
Arbeitsfeuchtigkeit
Arbeitsfeuchtigkeit
Einbauhöhe
Bewegungsgeschwindigkeit
Gute Emp ndlichkeit
maximum). Adjust the TIME switch, slide 5"
120º/360º
5s, 30s, 1min, 3min,
5min, 8min
-20~+40°C
<93%RH
1.8m~2.5m (Mauer)
2.2m~4m (Decke)
0.6~1.5m/s
Geringe Emp ndlichkeit

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis