CONNECTION
Warning! Danger of death through electric shock!
- must be installed by professional electrician
- disconnect power source
- cover or shied any adjacent live components
- check power supply is disconnected
Switch o the power.
Fix the bottom on the selected position with the in ated screw through the screw holes in
the side of the sensor.
Connecting the power and the load to sensor as per the connection-wire sketch diagram.
Switch on the power and test it
TEST
Turn the LUX knob clockwise on the maximum (sun), Turn the SENS knob clockwise on the maximum (+), Turn
the TIME knob anti-clockwise on the minimum (10s).
When you switch on the power, the light will be on at once. And 10sec±3sec later the light will be o automati-
cally. Then if the sensor receives induction signal again, it can work normally.
When the sensor receives the second induction signals within the rst induction, it will restart to time from the
moment.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX, the inductor load
could work when it receives induction signal.
NOTE: When testing in daylight, please turn LUX knob to
MOST COMMON PROBLEMS AND SOLVING WAYS
The load don't work:
1) Check the power and the load.
2) Whether the indicator light is turned on after sensing? If yes, please
check load.
3) If the indicator light does not turn on after sensing, please check if the
working light corresponds to the ambient light.
4) Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
1) Please check if in front of the detection window there are hinder that
e ect to receive the signals.

TECHNISCHE DATEN

Stromversorgung
Nennlast
Leistungsaufnahme
Standby-Leistung
Erfassungsreichweite
Umgebungslicht
Arbeitsfrequenz
(SUN) position, otherwise the sensor lamp could not work!
230V~ 50Hz
1200W
300W
P
: <0.9W
on
P
: <0.5W
sb
1-8m max (<24°C)
<3-2000LUX (regulowany)
5,8GHz
2) Please check the ambient temperature.
3) Please check if the signals source is in the detection elds.
4) Please check the installation height.
The sensor can't shut automatically the load:
1) If there are continual signals in the detection elds.
2) If the time delay is set to the longest.
3) If the power correspond to the instruction.
4) If the air temperature change near the sensor, air condition or central
heating etc.
DE
Erfassungsbereich
Zeitverzögerung
Arbeitsfeuchtigkeit
Arbeitsfeuchtigkeit
Einbauhöhe
Bewegungsgeschwindigkeit
Kraftübertragung
360º
min: 10s±3s
max:12min±1min
-20~+40°C
<93%RH
max: 1.5m~3.5m
0.6~1.5m/s
<0.2mW

Werbung