Herunterladen Inhalt Inhalt Diese Seite drucken

Accessories; Installation Information Battery Preparation; Battery Installation And Connection; Setting Of The Electronic Board For - Lavor MIDI-R Bedienungsanleitung

Inhaltsverzeichnis

Werbung

PHOTO C
1
BRUSH MOTOR THERMAL BREAKER
2
BATTERY POWER TEST
3
BRUSH MOTOR SWITCH
4
SUCTION MOTOR SWITCH
5
TRACTION MOTOR THERMAL BREAKER
6
TRACTION SPEED ADJUSTING KNOB
PHOTO D
1
SQUEEGEE INCLINATION ADJUSTING KNOB
2
SQUEEGEE FIXING KNOB
3
SQUEEGEE PRESSION ADJUSTING SCREW
4
SQUEEGEE BUMPER WHEEL
5
SQUEEGEE BLADES REPLACEMENT KNOB
6
SQUEEGEE WHEEL
7
SUCTION HOSE
PHOTO E
1
BATTERY COMPARTMENT
2
COVER OF THE SUCTION COMPARTMENT
3
SUCTION FILTER
4
SUCTION MOTOR
PHOTO F
1
BATTERY COMPARTMENT WITH 6V
BATTERIES
2
BATTERY CONNECTION
3
BATTERY CONNECTION DIAGRAM
PHOTO G
1
SELECTOR SWITCH FOR PB-ACID / GEL
BATTERIES
PHOTO H
1
SOLUTION WATER FILTER
2
BRAKE LEVER
PHOTO I
1
SPLASH GUARD FIXING SPRING CLIP
2
SPLASH GUARD
3
BUMPER WHEEL
4.2.2. BATTERY
If supplied, the Pb-Acid (if not dry charged) or gel bat-
teries are ready to be installed:
Positive pole - red
Negative pole - black
4.3.

ACCESSORIES

Your machine supplier can provide a complete and
updated list of all available accessories, such as
brushes, scrapers, disks, etc.
5.
INSTALLATION INFORMATION
5.1.
BATTERY PREPARATION
• The technical features of the batteries used must
match those indicated in the technical features sec-
tion. Using different batteries may cause serious
damage to the machine or may require them to be
charged more frequently.
• During installation or when performing any type of
battery maintenance, the operator must be equipped
with adequate safety accessories to prevent accidents.
Work far from open flames, do not short-circuit the bat-
tery poles, do not generate sparks and do not smoke.
The batteries are normally supplied full of acid solu-
tion (for the Pb-Acid type) and ready for use. In any
case, follow the steps indicated in the manual sup-
plied with the battery and carefully follow the instruc-
tions regarding safety and operating procedures.
5.2.
BATTERY INSTALLATION AND
CONNECTION
• These operations must be carried out by speciali-
sed personnel.
Disconnect the Anderson connector of the battery
wiring from the Anderson connector of the machine
wiring. Always hold the connectors with the hands
and never pull on the cables.
• Attach the battery wiring to the battery, connec-
ting the terminals only on the poles marked with
the same symbol (red wiring "+", black wiring "-")!
A battery short-circuit may cause an explosion!
After checking that all the controls on the panel are in
position "0" or at rest, connect the battery connector
to the machine connector.
• Close the battery compartment making sure not
to crush any wires.
5.3.

SETTING OF THE ELECTRONIC BOARD FOR

THE SECURITY STOP OF THE BRUSH MOTOR

In order to avoid the complete discharge of the bat-
teries, the machine is provided with a safety device.
When charge of the batteries goes below the safety
threshold, the electronic card (Photo G) stops the
operation of the brush motor.
☞ The operator must stop its work and recharge
the batteries.
Before the first use of the machine it is necessary to
set the electronic card for the operation of the ma-
chine with Pb-Acid or Gel batteries through the se-
lector (Photo G - 1).
To reach the electronic card it is necessary to remove
the plastic cap placed on the control panel; through
the hole it is possible to reach the selector with a
screwdriver;
☞ Put the selector to the right if the machine is provi-
ded with GEL batteries, or to the left if the machine is
provided with Pb-Acid batteries (Photo G - 1 ).
5.4.

MACHINE PREPARATION

• Before starting to work, wear non-slip shoes, gloves
29

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

A12Sigma 2-r

Inhaltsverzeichnis