CV-Values
CV's are usable with loco addresses (L), switch addresses(S) or with both (LS).
CV
Description
122 A1: lower limit
123 A1: upper limit
Attachment 1. (CV 29) – NMRA-Config
Bit
Off (Value=0)
0
Normal Driv. Direction
1
14 Speed Steps
5
Short Address
(CV 1)
7
Loco Address
Attachment 2. (CV 51 - 52) – Special functions A1 + A2
Value
0
0 = Continuous Operation
Continuous Symmetric Flashing
1..15
(Time Base 0,25 sec per unit)
(1..15)
Enhance timebase to 2 sec.
+ 32
Short Term Function, Monoflop
(1..15)
(Time Base 0,25 sec per unit)
+64
Switch Function!
(1..15)
Asymmetrical Flashing (Short) / Asymmetri-
+ 128 /
cal Flashing (Long)
+192
1/3 ON – 2/3 OFF
Default
Application
Reverse Driv.Direction
28 Speed Steps
Long Address
(CV 17+18)
Switch Address
Application
L/S
Range
16
L
5..50
32
L
5..50
On
Value
1
2
32
128
Standard Function
Output flashes symmetrically
Usable for all time programs. The
additional value must be added.
Output switches off automatically after
reaching the time limit. The additional
value must be added.
Short ON/Long OFF
The additional value must be added.
Note
Must be adjusted
to the RC servo
Must be adjusted
to the RC servo
Note
important for light
settings
Note
17