F11/12/13/15/17 eco 21-03-2001 13:51 Pagina 17
AIR CONDITIONING WITH INSTALLATION
Pinguino can also be semi-permanently
installed
30 cm
To install, proceed as follows:
• Make a hole in a wall communicating with
the outside or through the pane of a win-
dow. Respect the height and dimensions
given in figure D
in a window
pane
D
S e t t i n g u p
30 cm
in the
in the wall: for
optimum results,
wood sill of
insulate the sec-
a window
tion of the wall
with
suitable
insulating mate-
rial.
16
• Fit the flange
supplied to the hole.
17
• Fix the hose
to the coupling on the
back of the unit (figure A).
• Attach the end of the hose
16
flange
as shown in the figure E.
17
When the hose
is not attached, close the
hole with the bung on the flange
NOTE:
When the unit is installed semi-permanently,
we recommend leaving a door slightly open
(1 cm is enough) to ensure an adequate
exchange of air.
DEHUMIDIFICATION
Position the appliance in the room without
inserting the hose; in this way the dehumidi-
fied air will exhaust directly into the room.