4.5 Accessories
When needed put a disposable hood over the head before donning the Kite Pro and
pull the elastic band backwards.
When needed place a disposable visor on the visor (Only Kite Pro Heavy Duty).
See Par. 12 for all accessories and spare parts.
4.6 During use, leave the working area immediately in case one or more of the following
circumstances occur during use:
The air supply drops suddenly or fails completely.
The wearer becomes dizzy or unwell or can smell or taste contaminants.
The breathing becomes difficult.
Any part of the respirator becomes damaged.
The acoustic warning signal for low battery voltage sounds. This is a series of small
beeps, repeated every 30 seconds. After 15 minutes the unit will be switched off
automatically. Recharge the unit.
The acoustic warning signal for clogged filter sounds. This is a beep repeated every
second till the unit is switched off manually. Replace the filter.
4.7 After use
Switch off the Kite Pro by pressing the ON/OFF button.
Recharge the battery. See 4.1.
For cleaning and maintenance, see 5.

5 Maintenance and Inspection

After every use, the following parts should be examined to ensure safe and comfortable
use. See 12 for replacement parts.
5.1 Filter
Filter: the filter cannot be cleaned; replace when needed.
Warning: do not use compressed air in attempt to clean the filter.
5.2 Comfort pads
Replace when dirty or damaged.
5.3 Batteries
Defective batteries can only be replaced by authorised distributor workshops.
5.4 Charger
A defective charger cannot be repaired but must be replaced by a new one.