Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba RAS-M05N4KVSG-E Installationshandbuch Seite 5

Klimagerät (multi-typ)
Vorschau ausblenden Andere Handbücher für RAS-M05N4KVSG-E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 62
WARNING
• Never modify this unit by removing any of the safety guards or bypassing any of
the safety interlock switches.
• Do not install in a place which cannot bear the weight of the unit.
Personal injury and property damage can result if the unit falls.
• Before doing the electrical work, attach an approved plug to the power supply
cord.
Also, make sure the equipment is properly earthed.
• Appliance shall be installed in accordance with national wiring regulations.
If you detect any damage, do not install the unit. Contact your dealer
immediately.
• Do not use any refrigerant different from the one specifi ed for complement or
replacement.
Otherwise, abnormally high pressure may be generated in the refrigeration
cycle, which may result in a failure or explosion of the product or an injury to
your body.
• Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
• The appliance shall be stored in a room without continuously operating ignition
sources (for example: open fl ames, an operating gas appliance or an operating
electric heater).
• Be aware that refrigerants may not contain an odour.
• Do not pierce or burn as the appliance is pressurized. Do not expose the
appliance to heat, fl ame, sparks, or other sources or ignition. Else, it may
explode and cause injury or death.
• For R32 model, use pipes, fl are nut and tools which is specifi ed for R32
refrigerant. Using of existing (R22) piping, fl are nut and tools may cause
abnormally high pressure in the refrigerant cycle (piping), and possibly result in
explosion and injury.
• Thickness of copper pipes used R32 must be more than 0.8 mm. Never use
copper pipes thinner than 0.8 mm.
• After completion of installation or service, confi rm there is no leakage of
refrigerant gas. It may generate toxic gas when the refrigerant contacts with fi re.
• When the indoor unit is connected with multi-split R32 outdoor unit 3M26, 4M27
and 5M34.
Please see IMS outdoor unit installation manual and consult your dealer about
the minimum fl oor area.
• Comply with national gas regulations.
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis