Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Scope Of Delivery; Criteria For The Installation Location; Installing The Appliance - Bosch KGN86 Serie Gebrauchsanleitung

Kühl- und gefrierkombination
Vorschau ausblenden Andere Handbücher für KGN86 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

4 Installation and con-
nection
4.1 Scope of delivery
After unpacking all parts, check for
any transport damage and for com-
pleteness of delivery.
If you have any complaints, contact
your dealer or our after-sales service
→ Page 84.
The delivery consists of the following:
¡ Free-standing appliance
¡ Equipment and accessories
¡ Installation instructions
¡ User manual
¡ Customer service directory
¡ Warranty enclosure
¡ Energy label
¡ Information on energy consump-
tion and noises
4.2 Criteria for the installation
location
WARNING
Risk of explosion!
If the appliance is in a space that is
too small, a leak in the refrigeration
circuit may result in a flammable mix-
ture of gas and air.
Only install the appliance in a
space with a volume of at least
3
1 m
per 8 g refrigerant. The
volume of refrigerant is indicated
on the rating plate. → Fig. 
The weight of the appliance ex works
may be up to 110 kg depending on
the model.
1
Depending on the appliance specifications
2
Not in all countries
1
2
/
1
5
Installation and connection en
The subfloor must be sufficiently
stable to bear the weight of the appli-
ance.
Permitted room temperature
The permitted room temperature de-
pends on the appliance's climate
class.
The climate class can be found on
the rating plate. → Fig. 
Climate
Permitted room tem-
class
perature
SN
10 °C to 32 °C
N
16 °C to 32 °C
ST
16 °C to 38 °C
T
16 °C to 43 °C
The appliance is fully functional within
the permitted room temperature.
If an appliance with climate class SN
is operated at colder room temperat-
ures, the appliance will not be dam-
aged up to a room temperature of
5 °C.
Over-and-under and side-by-side
installation
If you want to install 2 refrigerating
appliances one over the other or side
by side, you must maintain a clear-
ance of at least 150 mm between the
appliances. Selected appliances can
be installed without a minimum clear-
ance. Ask your dealer or kitchen
planner about this.
4.3 Installing the appliance
Install the appliance in accordance
with the enclosed installation in-
structions.
/
1