An over temperature shutdown is indicated by a rapid flashing of
the system LED.

4.3 Over voltage- (transient) protection

Additional to the other protection circuits, the DDA2-XL is protected
against transient voltages on the mains supply.
But continuous overvoltage, which is an indicator for a faulty mains
supply, causes overheating of the protection device.
To prevent damage to the DDA2-XL by overheating of this device
and then by over voltage, there is a thermo-fuse which cuts off the
power supply.
If this happens, the temperature fuse must be replaced, either by us
or by an electrician.
5.

Display (LEDs on top )

The LEDs on the front panel have the following meaning:
DMX OK
green
SYS
yellow
Ch1-2
green
V
red
yellow
lit
= valid DMX512 signal
blink = signal error or no DMX signal
blink = system busy
rapid blinking = overtemperature shut down
brightness proportional to output 1 - 2
error on output 1 - 2 / short circuit
extern input closed