DDA2-XL
To store the new offsets set the 6
ON/OFF position once, all LEDs goes off as long the DDA2-XL
restarts.
2.3.2

Upper Offset (limit value)

The upper offset sets the lamp brightness for the DMX512 value
255 digit (100%).
The 7 at the left rotary code switch activates this mode and the
other two switches are for the offset value. This value is given to all
selected outputs.
To store the new offsets set the 6
ON/OFF position once, all LEDs goes off as long the DDA2-XL
restarts.
2.3.3

Control characteristic (curve)

The available curves can be programmed to each channel
individually. The switches 2 & 3 of the red DIP switch enables the
channel to which the selected curve will be stored.
The illustration on page 23 shows some of the curves where from
some are adjusted to LED Filament light bulbs out of our offer, one
according to the lighting standard and a few exotic to be
reprogrammed on request.
The control characteristic fixes the dependence of the brightness to
the DMX512 values. Either different special or linear curve may be
selected by the switches 2 & 3 of the red DIP-switch.
.
Img.
Choice
blue
[0/1]
red
[2]
yellow
[3]
green
[4]
brown
[5]
Type
adjusted to Sigor 6131001 classic 11W
adjusted to Segula 50295 vintage 6W
lighting standard LED
special from S-Type
cosine function
th
switch of the red DIP-switch to
th
switch of the red DIP-switch to
V2.02