BTL PF _ 400- _ _ _ _ -C12NL _ _ -0-000S04
Magnetostrictive Linear Position Sensor – Profile Style
Installation
NOTICE
Improper installation
Improper installation can compromise the function of the
BTL and result in damage.
► Ensure that no strong electrical or magnetic fields
are present in the direct vicinity of the BTL.
► Be sure to maintain the specified distances and
separations.
Dimensions see image.
Captive magnets
BTL5-F-2814-1S
Note when installing the magnet:
Avoid lateral forces.
Connect the magnet to the machine member with a
joint rod (see Accessories).
Floating magnets
BTL5-P-3800-2
C
BTL6-A-3800-2
C
2
english
BTL5-F-2814-1S
BTL5-P-5500-2
C
BTL6-A-3801-2
C
Installation (continued)
Observe the following when installing the magnet:
To ensure the accuracy of the magnetostrictive linear
position sensor, fasten the magnet to the moving
member of the machine only using non-magnetizable
screws (stainless steel, brass, aluminum).
The moving member must guide the magnet on a
parallel line to the BTL.
The distance A between the magnet and parts made of
magnetizable material must be at least 10 mm.
A
A
For distance B between the magnet and the BTL and
for the center offset C (see image) the following values
must be maintained:
Magnet type
BTL5-P-3800-2
BTL5-P-5500-2
BTL6-A-3800-2
BTL6-A-3801-2
1) The selected distance must remain constant over the entire measuring
length.
2) For optimal measurement results: 6...8 mm
When using multiple magnets a minimum separation of
65 mm must be maintained between them.
Any orientation is permitted. Mount the BTL on a level
surface of the machine using the provided mounting
clamps and cylinder-head screws.
In order to avoid resonant frequencies caused by
vibrations, we recommend positioning the
mounting clamps at irregular intervals.
Distance B
Offset C
1)
0.1...4 mm
±2 mm
5...15 mm
±15 mm
4...8 mm
2)
±5 mm
4...8 mm
2)
±5 mm

Werbung