4.7.4. Setting the ORP setpoint

Menu
From 200 to 900 mV, in 10 mV increments

4.7.5. Setting the hourly chlorine dosage

Menu
4.7.6. Setting the « CL injection Limit » alarm
The « CL injection limit » alarm is triggered when the cumulative volume of chlorine injected that day reaches a
specified value.
Menu
4.7.7. Setting the « ORP Regulation » alarm
The « ORP Regulation » alarm is triggered when the ORP measurement is out of tolerance (± 400 mV over the ORP
setpoint) for a specified time.
Menu

4.7.8. Real-time display of the cumulative volume of chlorine injected that day

Menu
Possible settings
Sub-menu
Specific instructions
To move to the next sub-
menu, press the OK key.
Possible settings
From 1 to 20 L, in 1 L increments
Possible settings
From 12 to 96 hrs, in increments of 12 hrs
None (read-only display)
-
in increments of 10 mL/h
Access to information
Press the OK key.
Default setting
670 mV
Possible settings
From 10 to 990 mL/h,
Default setting
2 L
Default setting
48 hrs
Default
setting
-
30 mL/h