4.6.5. Sensor settings
Marking on the connector
Menu
Sensor
Cover/Ext command
Flow
CL container
pH container
Temperature
Ext command : external command.
XX container : empty container sensor.
Type : this parameter does not appear if the corresponding mode is set to OFF.
Sensor activated
Cover
External command
Flow
CL container
Empty pH container
Temperature
CONNECTORS AT THE « Ext » PLUG
COVER
pH TANK
Cl TANK
FLOW
Setting
Mode
Type
Mode
Type
Mode
Type
Mode
Type
-
Configuration
Open cover
Closed cover
Command activated
Command not activated
Sufficient flow
No or insufficient flow
Empty container
Container not empty
Empty container
Container not empty
Regardless of the water temperature
* To modify this value, contact a professional.
Sensor to be connected
Cover or external command
Possible settings
Cover
OFF
Ext control
NO
NC
ON
OFF
NO
NC
OFF
ON
NO
NC
OFF
ON
NO
NC
ON
OFF
Specific display
-
-
-
-
-
-
Empty pH container
CL container
Flow
Default setting
Cover
NO
Depending on the model and options
NO
OFF
NO
OFF
NO
ON
ON : sensor activated.
OFF : sensor disabled.
NO : switch normally open.
NC : switch normally closed.
Dosing
of chlorine
Maintained
Forced setting
in MANU mode,
and hourly
dosing divided
by 5*
Maintained
Stopped
Maintained
Stopped
Stopped
Maintained
Maintained
Maintained
Maintained
Regulation
of pH
Maintained
Maintained
Maintained
Stopped
Maintained
Stopped
Maintained
Maintained
Stopped
Maintained
Maintained
10