Following functions can be set via the Steinel
Connect app:
– Time setting 5 s - 60 min
– Twilight setting 2-2,000 lux, daytime mode,
lux teach, time teach
– Reach adjustment
– Bluetooth interconnection
LED function
– Initialisation: LED flashes green.
– Bluetooth identification: LED slowly flashes blue.
– Normal mode: LED is OFF.
Time setting
The time you want the sensor switch controlled
light to stay ON for can be set to any period from
approx. 5 seconds to a maximum of 60 minutes.
Any movement detected before this time elapses
will restart the timer.
Note:
After the load switches OFF, it takes approx. 1 sec-
ond before movement can be detected again. The
load will only switch light ON again in response to
movement once this period has elapsed.
Twilight setting
The chosen sensor response threshold is infinitely
adjustable from approx. 2 to 2,000 lux.
Setting detection zone
The area covered by the sensor can be divided
into nine zones (Fig. 6.1):
– Four zones for close-up detection (6-9).
– Five zones for long-distance detection (1-5).
Each zone can be activated or deactivated
separately.
The boundary between close-up and long-distance
detection is at a distance of approx. 4.5 m, when
mounted at a height of 2.0 m.
The zones for close-up detection (6-9) can only
be deactivated if the neighbouring zone for
long-distance detection (1-5) is deactivated at the
same time.
The sensitivity of the 5 pyros can also be adjusted
individually. The pyros are assigned in line with the
various zones. It is only recommended to adjust
sensitivity if the chosen detection zone cannot
be suitably covered by activating/deactivating
individual zones.
Note:
If one or more of the outer zones (1 to 5) are
deactivated and several persons are present in
these zones at the same time, the sensor may
still switch ON.
Note:
When setting the time, it is recommended to select
the shortest period.
Note:
The twilight setting control must be set to daylight
mode when adjusting the detection zone and
performing the functional test in daylight.
Bluetooth interconnection (Connect Bluetooth
Mesh)
The sensor is configured via the Steinel Connect
app. Appropriate network keys are saved on a
smartphone or tablet the first time a connection
is made between the sensor and Steinel Connect
app. The key rules out any unauthorised access to
the sensor.
The network key must be shared for access via
another smartphone or tablet.

7. Cleaning and Maintenance

Hazard from electrical power.
Contact between water and live parts can result in
electrical shock, burns or death.
• Only clean tool in a dry state.
Risk of damage to property!
Using the wrong detergent can damage the light.
• Clean sensor switch with a moist cloth without
detergent.
8. Troubleshooting
Unit without power.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Break in wiring.
• Switch ON mains switch.
• Check wiring with voltage tester.
– Short circuit in mains power supply lead.
• Check connections.
Unit does not switch ON.
– Wrong twilight setting selected.
• Re-set brightness response threshold
– Mains switch OFF.
• Switch ON mains switch.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Detection zone too small or incorrect.
• Check and adjust detection zone.