ELECTRICAL CONNECTION

• It is mandatory to use a power point with a ground terminal, connected in accordance
with current safety regulations.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent,
or similarly qualified persons in order to avoid a hazard.
• The installation of this appliance and the connection to the electrical system should be
entrusted only to a qualified electrician.
• Protection against the parts under tension must be ensured after installation
• The data of connection necessary are on the stickers place on the hob casing near the
connection box.
• The connection to the mains must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for
example: circuit breakers, fuses, or contactors.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver. Place it in the slits and open the cover.
Mains
230 V~ 50/60 Hz
400 V~ 50/60 Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~ 1P+N
Put a bridge between terminal 1 and 2.
Attach the earth to the terminal "earth", the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase
400V~ 2P+N
Attach the earth to the terminal "earth", the neutral N to terminal 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution!
Frequent loosening and screwing of the screws on the connection box risks
damaging the efficiency of the tightness once screwed. It is therefore
advisable to keep screwing and unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.
4 weeks after installation, be sure to tighten again the screws in the terminal
block.
We cannot be held responsible for any accident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
2 Phases + N
equipped with a faulty earth connection
H 05 VV – F
3 x 2,5 mm²
H 05 RR – F
H 05 VV – F
4 x 1,5 mm²
H 05 RR – F
25
Protection
Cable
caliber
25 A *
16 A *