If no national or other requirements
exist, the appropriate minimum
distances in air, which define the outer
limits of the danger zone or the
approach zone, can be found in the
most recent version of the European
Standard 50110-1. The manufacturer's
≥ 10 m
recommendation is ≥ 10m
WARNING

RESIDUAL RISK

When using the remote control, a cutting process can be stopped
only on the cutting device once it has started.
It is therefore important to ensure that no one is in the danger zone.
Before the cutting process begins, access must be sealed off in
accordance with local regulations.
The operator of the remote control must select a location from
which the danger zone can be seen.

SPECIFIED CONDITIONS OF USE

The cable cutter is suitable for cutting insulated copper and alu-
minum cables and cables with light reinforcement that have been
disconnected from the power supply, depending on the cable type.
Cutting and splitting of cables with the aid of this cable cutter may
only carried out by personnel trained to work on underground
cables in accordance with local regulations.
The operator of this cable cutter must be instructed in the specific
dangers associated with using this cable cutter and in the essential
safety measures before working with it for the first time and at
least once a year thereafter.
USE
5
4
3
2
1
14

Device description

1 Blade retainer
2 Blades
3 Front handle / Insulated gripping surface
4 Slide switch / Trigger lock
5 LED
6 Trigger
6
8
7
11
9
10
12
13
15
17
16
13
This device contains a button-type/coin cell lithium battery.
A new or used battery can cause severe internal burns and
lead to death in as little as 2 hours if swallowed or if it enters the
body. Always secure the cover on the battery compartment. If it
does not close securely, stop the device, remove the battery and
keep it out of reach of children. If you believe that someone has
swallowed the battery or that it has otherwise entered the body,
seek immediate medical attention.
Only ever cut cables that have been disconnected from the power
supply!
Failure to comply with this instruction can lead to serious injury,
death, fire and other damage to property as a result of electric
shock, explosion and/or electric arcs.
Wear goggles.
The operating company must:
• make the operating manual available to the operator and
• ensure that the operator has read and understood it.
WARNING Read all safety warnings, instructions,
illustrations and specifications provided with this power
tool. Failure to follow the warnings and instructions may result in
electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
7 Release trigger
8 Handle / Insulated gripping surface
9 ONE-KEY battery door
10 Remote cut light
11 Remote cut switch
12 Hanger
13 Remote power switch with LED"1"
14 Remote button with LED "2"
15 Remote button with LED "3"
16 Remote cut indicators
17 Battery
Set-up of the working area
Before work begins, the cables must be disconnected and it must
be ensured that they remain de-energized throughout the work.
Local safety provisions and the regulations of the network operator
must be observed under all circumstances.
To affect, ensure and maintain disconnection of the power supply,
contact the network operator.
If it cannot be ensured beyond doubt that the cable or insulated
line has been disconnected, no work may be carried out.
Before the cutting process begins, access must be sealed off and
monitored in accordance with local regulations.