Herunterladen Inhalt Inhalt Diese Seite drucken

Honeywell EEM230-D-MO Montage- Und Bedienungsanleitung Seite 5

32 a-wirkenergiezähler 1-phasig mit modbus schnittstelle, pic. 1
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Assembly and operating instructions EEM230-D-MO
32 A Single Phase active power energy meter with Modbus interface, Pic. 1
Description
Energy meter with Modbus interface enables the reading
of all relevant data like meter reading, electricity, voltage,
power (active and reactive) and cos phi.
Technical data
Connection
Pic. 2
diagram
Dimensions
Pic. 3
Accuracy class
B according to EN50470-3,
1 according to IEC62053-21
Reference, Maxi-
I
= 5 A, I
ref
mum, initial current
operating voltage
230 V
, 50 Hz
AC
Tolerance −20%/+15%
Counting range
00 000,00...999 999,9 kWh
Connections
Conductor cross-section max. 6 mm
Main circuit
screwdriver pozi no. 1, slot no. 1,
torque 1,2 Nm
Connections
Conductor cross-section max. 2,5 mm
Control circuit
screwdriver pozi no. 0, slot no. 1,
torque 0,5 Nm
Operating
−25... +55°C (noncondensing
temperature
according standard EN50470)
Environment
Mechanical M2
Electromagnetic E2
Indicating elements
(Pic. 4)
T total (kWh)
Indicates the total consumption
T part (kWh)
Indicates the partial consumption.
This value can be reset.
P (kW)
Indicates the instantaneous power
U (V)
Indicates the voltage
I (A)
Indicates the current
2000 pulses/kWh
Pulsates according to the amount
of used power. Error indication
(line 1L/2L inverted) with pulse of
600/600 ms.
Made in Romania
4 319 5160 0 C
Notes before connecting
In order to avoid moisture in the meter due to condensate
build-up, acclimatise the meter at room temperature for
about half an hour before connecting.
Attention!
These devices must only be installed by a professional
electrician, otherwise there is the risk of fire or the risk of
an electric shock.
Operation of the LCD display
See page with LCD menu navigation.
= 32 A, I
20 mA
max
st =
Installation instructions
The energy meter can be attached to a 35 mm rail
(EN60715TH35).
2
,
The meter can be used only in installation cabinets.
Declaration of Conformity CE
,
2
We, Honeywell Technologies Sàrl, 1180 Rolle (Switzerland),
herewith declare, on our own responsibility that the
product:
which this certificate refer to, are in accordance with the
directive 2004/22/EG (MID) and the following standards:
ESD on equipment side: 13 kV.
Conformity Assessment Body:
Givisiez, February 2022
Signed: Maarit White, EMEA Quality Leader - BMS
2022-03-02
EEM230-D-MO-MID
EN50470 parts 1 and 3 (electronic meter), of
October 2006.
METAS-Cert, Nr. 1259
CH-3003 Bern-Wabern
UK Importer Address:
Honeywell Building Technologies
Building 5 Carlton Park
King Edward Avenue
Narborough, Leicester LE19 3EQ
Subject to change without notice
English

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis