• Continuity of protective conductors and protective bonding
• Insulation resistances
• Loop/Line impedance
• RCD test
• Function tests (including but not limited to):
-Vehicle state A,B,C,D
-Error handing (error "E",PE Error (Earth Fault),...)
-Communication (PWM signal)
-Mechanical locking of plug
-Rotary field/phase sequence
-Other tests
8-2.Connection of the Test Adapter to Charging Station
The Test Adapter can accept the following two connection cables:
• TYPE 2 test cable; for charging stations type 2 with panel mount with socket outlet or fixed cable with vehicle
connector (Included in scope of supply).
• TYPE 1 test cable; for charging stations type 1 with fixed cable and vehicle connector (Options).
7-Pole Male Connector
Test Adapter for Electric Vehicle Charging Stations
29