Notes to pressure sensitivity setting for weather forecasting:
The pressure threshold can be set to suit the user's requirement for weather forecasting from
2–4hPa (default 2hPa). For areas that experience frequent changes in air pressure requires
a higher hPa setting compared to an area where the air pressure is stagnant. For example if
4hPa is selected, then there must be a fall or rise in air pressure of at least 4hPa needed to
change the weather forecast icons.
Notes to storm threshold setting:
The storm threshold means the weather icons (rain and clouds) will begin to flash indicating
a dramatic change in pressure, indicating a storm. Similar to the general pressure sensitivity
setting it is possible to adjust the storm threshold sensitivity form 3–9hPa (default 4hPa). When
there is a fall over pressure threshold within 3 hours, the storm forecasting will be activated, the
clouds with rain icon and tendency arrows will flash for 3 hours indicating the storm warning
feature has been activated.
Indoor temperature
- Press the MENU key the eighth time to select the INDOOR TEMPERATURE section, IN-
DOOR TEMPERATURE section digits will start flashing. Enter the temperature unit mode,
press the UP/+ or DOWN/- key to select temperature unit between °C and °F
- Press ENTER key to select the following modes:
•
The indoor temperature high alarm setting. Press the ON/OFF key to on/off the alarm.
If alarm is enabled, an alarm symbol
tion has been enabled.
•
The indoor temperature low alarm setting. Press the ON/OFF key to on/off the alarm. If
alarm is enabled, an alarm symbol
has been enabled.
•
Reset the maximum indoor temperature value. When both the indoor temperature value and
MAX icon are flashing, hold the ENTER key for 3s, the maximum indoor temperature value
will be reset to current reading.
•
Reset the minimum indoor temperature value. When both the indoor temperature value and
MIN icon are flashing, hold the ENTER key for 3s, the minimum indoor temperature value
will be reset to current reading.
Indoor humidity
- Press the MENU key the ninth time to select the INDOOR HUMIDITY section, INDOOR HU-
MIDITY section digits will start flashing. Enter the indoor humidity high alarm setting mode,
press the ON/OFF key to on/off the alarm. If alarm is enabled, an alarm symbol
in the display indicating the alarm function has been enabled.
- Press ENTER key to select the following modes:
The indoor humidity low alarm setting. Press the ON/OFF key to on/off the alarm. If alarm is
•
enabled, an alarm symbol
enabled.
appears in the display indicating the alarm func-
appears in the display indicating the alarm function
appears in the display indicating the alarm function has been
EN - 79
EN
appears