The unit will work properly as long as the following three elements are present:
1. Fresh air
3.1 Location and Space Requirement
• The heat pump must be installed outdoors and more than 2m away from the pool. It can not
be installed indoors.
• Minimum clearance required for the heat pump installation as follow:
• Never install the unit in a closed room with a limited air volume in which the air expelled from
the unit will be reused, or close to garden plants that could block the air inlet. Such locations
impair the continuous supply of fresh air, resulting in reduced effi ciency, performance and
possibly preventing suffi cient heat output.
• During normal operations, the heat pump evaporator fi ns produce condensation water. The
amount of condensation produced varies according to ambient conditions. The higher the air
humidity, the higher the amount of condensation produced (several liters per day). The lower
heat pump panel acts as a condensation collection tray. Keep the drain hole clean.
• The heat pump must be positioned to avoid damages caused by water or condensation leaks.
Install suitable drainage outlets or collection containers.
• The heat pump must be fi xed and installed on a fl at, solid, vibration free and level support
(cement slab or prefabricated platform). Do not install the heat pump on unstable ground.
• To reduce noise wave echoes, do not install the heat pump in the immediate vicinity of vertical
walls and use the included anti-vibration pads during installation.
• Make sure the pump is not subject to rain water fl ows from nearby building roofs. Protruding
roofs without gutters could pour signifi cant amounts of water and/or debris on the heat pump
which could damage it. If necessary, install gutters or discharge outlets to protect the heat
pump.
• Make sure the heat pump is not within the range of any sprinkler or irrigation systems. If
necessary, install suitable protections.
SET UP INSTRUCTIONS
IMPORTANT
2. Electricity
3. Swimming pool water
Top 2000mm Above
Outlet
Inlet
H ea t
p um p
1000mm
EN
EN
Inlet
1000mm
11