FUNCTIONAL DESCRIPTION OF INVERTER GENERATORS
ECON FUNCTION
ECON FUNCTION
1. Start the engine.
2. Set the ECON switch to "ON".
3. Plug the device into an AC outlet.
4. Make sure the AC indicator light is on.
5. Turn on the electrical device.
IMPORTANT!
"ON" MODE
"ON" MODE
When the ECON switch is in the "ON" position, the control unit monitors the engine speed, reducing it commensurate
with the connected load. If the engine speed is not enough to generate electricity to provide the load, the control unit
will automatically increase the engine speed.
As a result, fuel consumption is optimized and noise levels are reduced.
"OFF" MODE
"OFF" MODE
The ECON switch must be set back to "OFF" when using electrical devices requiring a high starting current, such as a
compressor or submersible pump.
PARALLEL FUNCTION
PARALLEL FUNCTION
The total output power of the generators can be increased by connecting two inverter generators together using the
Parallel Unit from Könner & Söhnen. Parallel connection of two generators ensures total rated output power of these
generators. When the generators are connected in parallel, the power loss is 0.3 kW of the total rated power that
can be obtained.
DISCONNECT ALL DEVICES BEFORE STOPPING THE GENERATOR!
DISCONNECT ALL DEVICES BEFORE STOPPING THE GENERATOR!
Do not stop the generator with the devices turned on. This may disable the generator or devices connected to it!
STOPPING THE ENGINE
STOPPING THE ENGINE
To stop the engine, proceed as follows:
1. Disconnect all devices connected to the generator, then
disable the ECON mode.
2. Allow the generator to run idle for approx. 1-2 minutes.
3. Turn the fuel valve to the "OFF" position.
4. Set the engine switch to the "OFF" position.
5. Turn the air choke control knob to the "OFF" position.
6. After the generator stops, allow it to cool down and close the
air vent on the fuel cap (set to OFF,
Works, specified in "Technical maintenance" section, are to be regularily performed. If the the generator user has
no possibility to perform regular maintenance independently, it is necessary to address the official service center to
registrate an order for such works performance.
You can find a list of service center addresses in your warranty card.
The ECON switch must be set to "OFF" to increase engine speed
to nominal.
TECHNICAL MAINTENANCE WORKS