IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal
(operating) power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still hot after
operation to ensure quick and complete oil draining.
3. Check and clean the air filter, fuel filter and spark plug.
ENGINE START
ENGINE START
IMPORTANT!
IMPORTANT!
IMPORTANT!
1. Check oil level.
2. Check fuel level.
3. Open the vent on the fuel cap to the "ON" position.
4. Close the air choke.
5. Turn the fuel valve handle to the "ON" position (OPEN).
6. Set the engine switch to the "ON" position.
7. Pull the manual starter until a slight resistance is felt, then pull it
toward you relatively sharply. Slowly turn the manual starter by hand,
do not release it abruptly.
8. Open the air choke.
9. Allow the generator to run idle for approx. 1-2 minutes.
10. Connect the device you need to the generator outlet.
FUEL TANK VENT
FUEL TANK VENT
The fuel tank cap is provided with a vent for sealing the fuel tank.
The ventilation lever should be used; leave the ventilation lever in the
"OFF" position to reduce the possibility of fuel leakage.
IMPORTANT!
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn off the generator. Allow the
generator to run idle for 1-2 minutes so that it cools down.
Ensure that the devices are in good condition before connecting them to the generator. If the connected device
suddenly stopped working, immediately disconnect the load on the emergency stop switch, disconnect the device
and check it out.
Useful tip: If the engine stalls or does not start, turn the engine
switch to the "ON" position, and then pull the manual starter.
If the oil level indicator flickers for several seconds, add oil and
restart the engine.
Each time you start the generator, be sure to check oil and fuel level
Before starting the generator, connect the ground wire to the
ground terminal.
Useful tip: to ensure long-term operation of the generator engine,
it is important to observe the following tips:
Fuel tank cap
Ventilation lever
Close
Open