Dust/Chip Extraction (see figure B)
Dusts from materials such as lead-containing
coatings, some wood types, minerals and
metal can be harmful to one's health. Touch-
ing or breathing-in the dusts can cause aller-
gic reactions and/or lead to respiratory infec-
tions of the user or bystanders.
Certain dusts, such as oak or beech dust, are
considered as carcinogenic, especially in
connection with wood-treatment additives
(chromate, wood preservative). Materials
containing asbestos may only be worked by
specialists.
– Use dust extraction whenever possible.
– Provide for good ventilation of the work-
ing place.
– It is recommended to wear a P2 filter-
class respirator.
Observe the relevant regulations in your
country for the materials to be worked.
Mounting the Extraction Adapter
Before mounting the extraction adapter 24,
bring the machine in the upper starting position
by actuating the release lever 16.
Insert the extraction adapter 24, turn the extrac-
tion adapter 24 clockwise to the stop until this
can be felt to engage (bayonet catch), and fas-
ten it with wing bolt 25.
47
Connecting the Dust Extraction
Insert an extraction hose (Ø 35 mm) 23 (acces-
sory) into the mounted extraction adapter. Con-
nect the extraction hose 23 to a vacuum cleaner
(accessory).
Bosch Power Tools
Note: For router bit
diameters larger
than 30 mm, the in-
sert 47 must be re-
moved from the ex-
traction adapter 24
by pressing on the
clamping shackles.
The machine can be plugged directly into the re-
ceptacle of a Bosch all-purpose vacuum cleaner
with remote starting control. The vacuum clean-
er starts automatically when the machine is
switched on.
The vacuum cleaner must be suitable for the ma-
terial being worked.
When vacuuming dry dust that is especially det-
rimental to health or carcinogenic, use a special
vacuum cleaner.
Operation

Starting Operation

Observe correct mains voltage! The voltage
of the power source must agree with the
voltage specified on the nameplate of the
machine. Power tools marked with 230 V
can also be operated with 220 V.
Preselecting the Speed
The required speed can be preselected with the
thumbwheel 17 (also while running).
1 – 2
low speed
3 – 4
medium speed
5 – 6
high speed
The values shown in the chart are standard val-
ues. The necessary speed depends on the mate-
rial and the operating conditions, and can be de-
termined by practical testing.