Installation
You can also mount the e:cue SYMPL Node on any flat vertical surface.
Use a 3 to 3.5 mm screw for the hanger hole.
For mechanical stability, mounting on a rail is recommended.
4.3

Ethernet connection

The pin-assignment of the Ethernet port corresponds to RJ45 standards.
You can use every common Ethernet component, like cable, splitters, and
switches. Connect the SYMPL e:bus Node at the designated Ethernet
interface with a patch cable (RJ45, CAT5).
Never connect more than one SYMPL Node in factory state
i
to a network. The identical IP addresses will conflict and
disturb proper communication.
The Ethernet port of the SYMPL Node is not designed for
i
inter-building connections with power and lighting transients.
Use only intra-building networks to connect the SYMPL
Nodes and Cores.
4.4

e:bus connection

The SYMPL e:bus Node can control up to eight e:bus devices with its e:bus
interface. Connect e:bus devices to the SYMPL Node using 4-pin terminal
plugs at the e:bus interface of the SYMPL Node.
The appropriate pin assignment is defined as follows:
From left to right: -, -, +, +
It is recommended to use twisted pair cabling.
Bus configuration
The e:cue SYMPL e:bus Node has a switch to select if a straight bus or a
free bus topology is used:
left: free topology
right: bus topology.
14