Setting
 RC. setting mode (Main/sub, Clock type, Password change)
 Detailed settings (Vent output setting, Temp sensor setting, Temp display
setting)
1
Press and hold the 3 buttons for
4 seconds or more simultaneously.
,
, ►
2
Select the item to set.
▲ ▼ →

RC. setting mode

3
Set.
(Select the Code no. and Set data.)
▲ ▼ → ► →
(Repeat)
Code
no.
01
Main/sub
02
Clock type
Password
2F
change

Detailed settings

3
Set.
(Select the indoor unit number, Code no. and Set data.)
▲ ▼ → ► →
(Repeat)
Code no.
Vent output
31
setting
Temp sensor
32
setting
Temp display
33
setting
12
(EN)
Set this when using 2 remote controllers.
Set the type of clock display.
Set the administrator password.
Set this when connecting a commercially sold fan, etc. to the
ventilation fan output "FAN DRIVE:2P (White)" on the indoor control
board.
*Dedicated cables (optional) are required.
Set this when measuring the room temperature with the room
temperature sensor of the remote controller.
• When using the main and sub controllers, the main one is
enabled.
• When controlling in group, set this for the main indoor unit number.
(No setting is required for sub indoor units.)
• When using with the remote sensor in combination, set the indoor
unit setting data.
Set the type of temperature display.
Code no.
Set data
Set data
• 0000: Sub
• 0001: Main (factory
setting)
• 0000: 24 hours
• 0001: 12 hours
(AM/PM)
• 0000 to 9999
• 0000 (factory setting)
Indoor unit
Set data
number
Code no.
Set data
• 0000: Not connected
• 0001: Connected
• 0000: Indoor unit
• 0001: RC
• 0000: °C
• 0001: °F

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis