GB
Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with low-pressure displacement water heaters is
not possible.
Technical data
• Flow pressure
min. 0,5 bar / recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure is greater than 5 bar, fit pressure reducer.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 3 bar flow pessure
• Temperature
Hot water inlet:
Recommended (energy saving):
• Supply voltage:
6 V-Lithium battery (Type CR-P2)
• Automatic safety stop (factory setting):
• Tails time (factory setting):
• Reception range with to Kodak Gray Card, grey page,
8 x 10", landscape (factory setting):
• Type of protection:
• Battery check (control light)
• Water connection
Special accessory, see spare parts fold-out page I.
• With the infrared remote control (ref.-no.: 36 206) the
following settings and changes could be conducted.
Adjust reception range (5 - 20cm)
Adjust tails time (0 - 10 s)
Set and activate continuous running (thermal
desinfection)
Switch off solenoid valve
Restore basic adjustment
Test mode
waterless simulation
=
Adjust safety stop (2 - 420 s)
Activate and set automatic flushing
• Special wrench (ref.-no.: 19 132) for dismounting flexible
hoses.
• Theft secure aerator (ref.-no.: 36 133).
• Vandalism hampering concealed mixing spindle (ref.-
no.: 36 209).
• Base to increase mixer and sensor (ref.-no.: 36 210).
• Vandalism hampering anti twist plate (ref.-no.: 42 919).
The anti-twist plate is not combinable with base and not
useful for products with pop up waste set.
Permission and conformity
This product corresponds to the request of the
appropriate EU guidelines.
The agreement assertions can be requested under the
following address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
max. 10 bar
16 bar

Disposal note

Dispose battery properly!
approx. 6 l/min.
max. 70 °C
60 °C
Installation
60 s
Flush pipe lines thoroughly!
1 s
approx. 13cm
Mounting
IP 59 K
Refer to the dimensional drawings on fold out page I.
Lift rod (A) must be inserted into the mixer body during
cold - right
installation, see fold-out page II, Fig. [1].
hot - left
Mount mixer to basin, see Figs. [1] to [3].
Install pop-up waste set (28 910), see fold-out page I.
Seal plug-hole rim!
Connection
The cold water supply must be connected on the right and the
hot water supply on the left.
Screw adapter (B) by using the seal (C) to the service valve,
see Fig. [4].
For the guarantee of a permanently error free operation
the installation of the enclosed adapters with filter
respectively non-return valve is mandatory necessary!
Open cold and hot-water supply and check connections
for leakage.