Applications
Infrared fitting, suitable for:
• Direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Technical Data
• Minimum flow pressure without
downstream resistances
• Minimum flow pressure with downstream resistances 1 bar
• Recommended flow pressure
• Operating pressure
• Test pressure
• Flow rate at 3 bar flow pressure:
- without downstream resistances
- with spout 42 132 / 42 133
• Temperature
• Supply voltage
• Automatic safety shut-off:
(factory setting)
• Battery check (flashing signal)
• Automatic flushing (factory setting: deactivated)
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (factory setting):
- Start / stop water flow
- Automatically stop water flow
• Type of protection
• Run-on time (factory setting)
• Minimum flow rate
If static pressure exceeds 5 bar, a pressure reducing valve
must be fitted.
Special accessories, see Replacement parts, fold-out page I.
• The following settings can be made and changed with the
infrared remote control (Prod. no.: 36 206):
- Set reception range (3 -50cm)
- Set run-on time (0 - 10 s)
- Switch off fitting
- Restore basic settings
- Test mode = waterless simulation
- Set automatic safety shutoff (5 - 420 s)
- Change type of detection
- Activate and set automatic flushing
• 42mm isolating valve (Prod. no.: 42 277).
• 192mm spout (Prod. no.: 42 132).
• 160mm spout (Prod. no.: 42 133).
• Self-closing cartridge (Prod no.: 43 497).
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk

Approval and conformity

The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
0.5 bar
1 -5 bar

Disposal note

max. 10 bar
10 bar
Dispose of the battery properly.
approx. 15 l/min
approx. 9 l/min
max. 70 °C
6 V lithium battery
(type CR-P2)
60 s

Installation

Flush pipes thoroughly.
Install fitting and fasten
Refer to the dimensional drawing on fold-out page I.
3 - 7cm
> 35cm
• Fit escutcheon (A) and screw on fitting,
IP 56
see fold-out page II, Fig. [1].
1 s
= 5 l/min
Open hot and cold water supply and check connections
for water-tightness!

Operation

The infrared-electronic system emits invisible, pulsed light.
The infrared electronics are set as follows at the factory:
Start water flow
Hold the hand at a distance of 3 - 7cm in front of the sensor
system (B), see Fig. [2].
Stop water flow
When a person moves out of the detection zone or when the
hand is held near the sensor system again, the water flow is
stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Note:
For anonymous use, we recommend affixing the enclosed
sticker (Prod. no.: 42 178).
This product conforms to the requirements of the
relevant EU guidelines.
4