Herunterladen Inhalt Inhalt Diese Seite drucken

Respekta CH 1295 IXC N Bedienungs-/Montageanleitung Seite 26

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
Failure
Light on, but motor
does not work
Beside the above mentioned actions, check the following:
Light does not work,
motor does not run
Oil leakage
Vibration of the hood
Insufficient suction
The hood is instable
fi200817
16. Cooker Hood Trouble shooting
Cause
One flapp of the one-way valve is
blocked. One-way valve not installed
correctly
The capacitor is damaged
Motor bracket defective / jams
Suspicious smell from the motor
Light damaged
No power, device cable not properly
connected
One-way valve leaking
Leakage from the junction of the
chimney with the hood body
A flap of the on-wey valve is
damaged and causing vibrations
The motor is not tightly mounted
The hood is not tightly fixed
The distance between the hood and
the hob is too big
Too much air flow from open doors
or windows
Mounting bracket not firmly fixed
Hood fastening screws not firmly
tightened
10
Solution
Eliminate the blocking
or replace the one-way
valve
Replace capacitor
Replace motor
Replace motor
Replace lights
Check fuse, connect
cable correctly (electric
diagram)
Seal the junction with
suitable means
Seal the junction with
suitable means
Replace the complete
one-way valve
Fix the hood tightly
Fix the hood tightly
Lower the position of
the hood
Close windows and
doors
Tighten the screws on
the mounting bracket
securely
Tighten the fastening
screws firmly
GB

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis