Installation
Under any circumstances, make sure the ceramic cooker hob is well
ventilated and the air inlet and outlet are not blocked. Ensure the
ceramic cooker hob is in good work state. As shown below
Note: The safety distance between the hotplate and the
cupboard above the hotplate should be at least 760mm.
• The work surface is square and level, and no structural members interfere with
space requirements
• The work surface is made of a heat-resistant material
• If the hob is installed above an oven, the oven has a built-in cooling fan
• The installation will comply with all clearance requirements and applicable
standards and regulations
• A suitable isolating switch providing full disconnection from the mains power
supply is incorporated in the permanent wiring, mounted and positioned to com-
ply with the local wiring rules and regulations. The isolating switch must be of an
44
!
A: 760 mm
!
B: min. 50 mm
C: 20 mm
D: Air gap/Intake
E: Air exit (5 mm)