dangerous and can rotate at great speed,
causing injury to persons nearby and blowing
foreign objects into the air. Do not attempt to
catch the hose, evacuate all onlookers from the
risk area, turn off the air supply, switch off the
compressor with the ON/OFF switch and then
remove the hose from the compressor.
Symbols
The following symbols can be of importance
for how you should use your power tool. Make
sure you understand the symbols and their
significance.
Read the instructions.
Approved in accordance with
the relevant EU directives.
Risk of burns.
Warning – live parts.
Risk of automatic start.
Do not open the tap until the
air hose is connected.
Sound power level.
97
Wear ear protection.
Recycle as electrical waste.
TECHNICAL DATA
Rated voltage
Output
Speed no load
Max. operating pressure
Air tank
Displacement
Air emission
Air emission at 6 bar
Sound pressure level, LpA
Sound power level*, LwA 94 dB(A), K= 3 dB(A)
Sound power level**, LwA 97 dB(A), K= 3 dB(A)
* Measured, ** Guaranteed
Always wear ear protection.
The declared values for vibration and noise,
which have been measured by a standardised
test method, can be used to compare different
tools with each other and for a preliminary
assessment of exposure. The measurement
values have been determined in accordance
with EN 1012-1:2010.
WARNING!
The actual vibration and noise level when
using tools may differ from the specified
maximum value, depending on how the
tool is used and the material. It is therefore
necessary to determine which safety
precautions are required to protect the user,
based on an estimate of exposure in actual
operating conditions (taking into account all
stages of the work cycle, e.g. the time when
the tool is switched off and when it is idling,
in addition to the start-up time).
DESCRIPTION
The compressor compresses atmospheric
air and charges an air tank with compressed
air. The compressor motor is switched off
automatically by a pressure switch when the
maximum permitted pressure in the air tank is
achieved. If the pressure switch is not working,
EN
230 V ~ 50 Hz
1200 W
4000 rpm
8 bar
6 l
Approx. 180 l/min
Approx. 120 l/min
Approx. 50 l/min
85 dB(A), K= 3 dB