Herunterladen Diese Seite drucken

Benning Tritest Easy Bedienungsanleitung Seite 10

Phasen-/ drehfeldprüfer

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
approx. 3 seconds. An acoustic signal is emitted and the LED
red color.
-
As soon as the LED
1
with the assumed phase (external conductor) L2 within 2 seconds. An
acoustic signal is emitted and the LED
-
As soon as the LED
times, the phase sequence is indicated via the probe tip.
-
probe tip lights in green color: clockwise phase sequence (phase 1 before
phase 2)
-
probe tip lights in red color: counter-clockwise phase sequence (phase 2
before phase 1)
-
probe tip flashes in green color: equal phase (phase 1 = phase 2)
-
probe tip flashes in green/red color: phase sequence could not be deter-
mined
Note:
Always hold the device steady during the measurements without wobbling.
Mains failures or a lacking mains quality might affect the correct functioning
of the device.
7.
Battery replacement (figure A)
-
Do not apply voltage to the device when the battery compartment is open!
-
Remove the battery compartment cover
the screws and remove the used batteries.
-
Insert new micro batteries (LR03/AAA) into the tester observing correct
polarity (positive pole first).
-
Place the battery compartment cover 7 back onto the tester and tighten the
screws.
8.
Technical data
-
regulation: DIN EN 61010-1, DIN EN 61326
-
nominal voltage/frequency range: 200 V to 1,000 V AC/45 to 65 Hz
-
overvoltage category: CAT III 1,000 V/CAT IV 600 V 
-
contamination level: 2
-
protection category: IP 53 (DIN EN 60529), protection against dust and
water spray
-
automatic switch-off: after approx. 5 minutes
-
operating temperature range: - 10 °C to + 40 °C, air humidity ≤ 75%, 40 °C
to + 50 °C, air humidity ≤ 45 %,
-
storage temperature range: - 20 °C to + 60 °C, air humidity ≤ 80% (without
batteries)
-
dimensions of the tester (L x W x H): approx. 153 x 20 x 25 mm
-
weight: approx. 40 g (incl. batteries)
-
battery type: 2 x micro, LR03/AAA (1.5 V)
The TRITEST
®
tery being exhausted!
9.
General maintenance
Clean the exterior of the device with a clean dry cloth.
If there is contamination or deposits in the area of the battery or the battery
housing, clean these areas as well by means of a dry cloth. If the device is
stored for a longer period of time, remove the batteries from the device!
10. Environmental protection
At the end of product life, dispose of the unserviceable device as well
as used batteries via appropriate collecting facilities provided in your
community.