5. Appendix
5.1. RAID Troubleshooting
Normally
If problems concerning your RAID controller should arise, check the following
points before contacting our hotline or consulting your local dealer:
-
Is the RAID controller properly installed?
-
Are the cable connections between the RAID controller and the hard disks
correct?
-
Is a power cable attached to each hard disk?
-
Check the device manager to see if the driver is properly installed.
If all the conditions mentioned above are fulfilled, you can first partition and then
format the array. Please follow the instructions of the manufacturer of your operating
system. If the problem still cannot be solved, contact your local dealer or our free
hotline.
RAID1 Rebuilding a Defective Mirrored Array
If one hard disk of a mirrored array fails to function, you will receive the error
message "Incomplete RAID set" from the DC-154 BIOS while booting your computer.
To rebuild the defective mirrored array, carry out the following steps:
-
Check the connections of the defective hard disk. In case of a physical fault of the
hard disk, it must be replaced by a new hard disk which with regard to its size must
at least correspond to the hard disk still intact.
-
Start the computer and call up the DC-154 RAID BIOS by pressing the keys <Ctrl
+S> or <F4>.
-
You will now have to define the new drive as "SPARE DRIVE" (see chapter
2.4.2.1)
-
The Windows driver now causes the drive to be automatically integrated into the
defective RAID array.