Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Hilti SCO 6-A22 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SCO 6-A22:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
4
Consumables
The following accessory tools can be used with the cut-out tool:
Drywall
Guidepoint bit (3.2 mm (1/8"))
Standard bit (3.2 mm (1/8"))
Universal guidepoint bit (4 mm (5/32"))
Window/door guidepoint bit (6.4 mm (1/4"))
Metal
Metal bit (4 mm (5/32"))
5

Technical data

5.1
Cut-out tool
Rated voltage
Rated speed under no load
Weight in accordance with EPTA procedure 01
Weight B 22/2.6
Weight B 22/3.0
Weight B 22/5.2
Operating temperature
Storage temperature
Clamping nut
Collet diameter
Cutting bit shank diameter
5.2
Battery temperature ranges
Battery operating temperature
Battery charging starting temperature
Battery storage temperature
5.3
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise information
Sound power level (L
WA
Uncertainty for the sound power level (K
18
English
)
)
WA
SCO 6-A22
21.6 V
30,000 /min
1.4 kg
0.48 kg
0.58 kg
0.78 kg
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
16 mm (5/8") external
hexagon
3.2 mm (1/8"), 4 mm
(5/32"), 6.4 mm (1/4")
3.2 mm (1/8"), 4 mm
(5/32"), 6.4 mm (1/4")
−17 ℃ ... 60 ℃
−10 ℃ ... 45 ℃
−20 ℃ ... 40 ℃
90 dB(A)
3 dB(A)
2194405
*2194405*

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis