2.4.1 Types of installations
Listed below are definitions and requirements for correct installation of an
exhaust flue in accordance with Italian Standard UNI10683:
FLUE : a vertical duct for collecting and expelling, at an appropriate height
from ground, the fumes coming from a single unit and, where permitted,
more than one.
FLUE technical requirements :- it must be fumetight, isolated and
insulated depending on its use;
- it must have a mainly vertical path with axis deviation < 45°;
- it must be placed at a suitable distance from flammable materials by
means of insulation or air gap;
- it must preferably have a continuous, free and independent round internal
section;
- it is advisable for the flue to have an inspectionable chamber for the
collection of solid materials
- and any condensate, placed under the beginning of the fume duct.
FLUE CONNECTION or DUCT: duct or connection element between the
unit and flue for evacuation of fumes.
DUCT technical requirements: - it must not cross rooms where the installation of combustion units is not allowed;
- flexible metal tubes or fibre cement pipes are prohibited;
- the use of counter-sloping elements is prohibited;
- horizontal sections must have an upward slope of at least 3%;
- the length of the horizontal section must be minimal and not more than 3 m;
- there must not be more than 3 changes of direction without the T union;
- with change of direction > 90° a max. of 2 bends can be used with length in horizontal projection not exceeding 2 m.
- the fume duct must have a continuous section and allow the recovery of soot.
CHIMNEY CAP : a device placed on the top of the flue to facilitate the dispersion of fumes into the atmosphere.
CHIMNEY CAP technical requirements
- it must have a useful section not less than double the internal section of the flue;
- it must prevent the entry of rain and foreign bodies and ensure the discharge of fumes in any
atmospheric condition;
- it must ensure an adequate dilution of fumes and be positioned outside the backflow area;
- it must be without mechanical means of suction.
The direct discharge of fumes must take place on the roof and not towards closed spaces (even open air).
2.5 Turbulator and brazier position check
Before lighting the boiler, make sure the brazier is in the correct position, i.e. fitted in the special slots Also make
sure the turbulator shaker device is resting in the lower position. An incorrect position of the brazier and/or
turbulators can result in malfunctioning and excessive creation of dusts and unburnt products.
At every unit lighting, check the correct position of the brazier and turbulator shaker device.

2.6 Electrical connection

Connect one end of the power cable to the rear socket of the stove, and the other to a wall socket.
The voltage supplied by the system must match that specified on the stove data plate and in the technical data
section of this manual.
During stove idle periods it is advisable to remove the power cable.
- Make sure the electrical system complies with the regulations and has an earth connection and
differential switch in compliance with the current Standards
- The power cable must never touch the stove exhaust pipe.
All manuals and user guides at all-guides.com
:
- it must have a section equivalent to that of the flue;
45
Antiwind grille
Comignolo
antivento
Flue
Canna
fumaria
Min. distance 0.2m
Distanza minima
DOMUSFIRE C17-C24
Flue
Raccordo
connection
fumi
Inspectiona
Camera
ble chamber
ispezionabile
Outside air inlet
Presa d'aria
min. 100 cm²
esterna
2
min.100 cm

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Domusfire c24

Inhaltsverzeichnis