2 TRANSPORT AND INSTALLATION

2.1 Conditions of supply, transport and storage

The boiler is delivered wrapped in nylon protection and packed on a pallet + wooden crate after completing the
production cycle and the functional testing on the assembly line at the manufacturer's factory.
The unit complete with packing can be lifted using a lift truck, inserting the forks (of suitable length) in the special
spaces in the wooden pallet Make sure the equipment used for lifting and transport can take the boiler's weight,
specified on the data plate and in this manual.
Avoid taking the load in areas where it could be a danger if dropped.
- During transport and storage, avoid exposure to rain or persistent humidity.
- The boiler must only be moved in a vertical position by forklift, resting on the base.
- Use suitable equipment to remove the boards or wooden parts of the boiler packing.
- Disposal or recycling of the packing must be done by the end user, complying with local regulations on
waste and keeping it out of the reach of children or disabled persons.

2.2 Place of installation, positioning and fire-prevention safety

After preparing the water and electrical connections (by a qualified technician), open the packing, remove the boiler
from pallet and place it in the desired location, making sure it complies with the requirements in this manual.
Set the boiler down on the floor carefully without bumping and position it in the required place. Make sure the floor
can take its weight, otherwise see a specialised technician.
After removing the protective packing, be careful not to damage the mechanical and electrical parts by knocking or
splashing with water.
The place of installation must be sufficiently ventilated to allow the removal of any combustion smoke leaks.
The unit is suitable for operation in technical environments with min. temperature not below 0°C; it comes complete
with an antifreeze function that activates the heating pump for system water temperatures below 6°C, safeguarding:
heating chamber, heating/DHW circuit. The antifreeze function is active only when the boiler is electrically powered.
The boiler must also be suitably separated from flammable or combustible materials by air spaces or the use of
appropriate protective insulation; floors and/or ceiling-coverings in flammable or heat sensitive material must be
protected by panels of insulating material.
Make sure there are spaces at the sides and rear of the boiler, necessary for servicing and cleaning the unit, fume
ducts and the flue.
Also make sure the pellet hopper is easily accessible for loading the fuel.
The minimum distances for maintenance and safety must comply with the following table:
OPTIONAL
SUPPLEMENTARY
HOPPER
All manuals and user guides at all-guides.com
43
BOILER
A = 500 mm
B = 500 mm
C = 500 mm
D = 1000 mm
L = 1350 mm
P = 700 mm
DOMUSFIRE C17-C24