Reassembly
Connect high performance filter. At this time, make sure
to twist high performance filter so that securing lip is
firmly locked into the cleaner unit.
► Fig.13: 1. High performance filter
► Fig.14: 1. Securing lip
NOTICE:
Always be sure to check that high perfor-
mance filter is loaded correctly prior to using cleaner.
If they are not loaded correctly, dust will get into the
motor housing, and cause motor failure.
If the problem as described later occurs, high per-
formance filter is not loaded correctly. Reload them
correctly to rectify problem.
Attach the capsule. Align the mark on capsule with the
mark on the handle and then firmly twist capsule in the
direction of arrow until it is secured.
► Fig.15: 1. Mark 2. Handle 3. Capsule
NOTE: Always remove dust ahead of time, as suction
power will be reduced if there is too much dust in
cleaner.
Problem Examples
The securing lip of high performance filter is not firmly
locked into groove of cleaner housing.
► Fig.16: 1. Securing lip 2. Groove of cleaner housing
Installing or removing stay / HEPA
filter
Optional accessory
For the stay and sponge filter
To remove the stay, push up the bottom part of pillars
of the stay with your fingers and release its groove from
the protrusion on the cleaner. After that, remove the
sponge filter.
► Fig.17: 1. Stay 2. Sponge filter
To install, align the grooves on the stay with the protru-
sion on the cleaner and push until it clicks.
Insert the sponge filter between the pillars and set it in
the original position.
For the HEPA filter
When installing the HEPA filter, fit the groove of the
HEPA filter with the protrusion on the cleaner. Then, put
the prefilter or the high performance filter on the HEPA
filter and twist it to secure. To remove, follow the instal-
lation procedure in reverse.
► Fig.18: 1. HEPA filter 2. Prefilter
► Fig.19: 1. HEPA filter 2. High performance filter

OPERATION

CAUTION:
Do not move your face close to
the air vent when operating the cleaner. If foreign
objects are blown into eyes, it may result in personal
injury.
Installing or removing the cleaner
attachment
CAUTION:
After installing attachment,
check if it is securely installed. If the attachment
is installed imperfectly, it may come off and cause
personal injury.
CAUTION:
Be careful not to hit your hand on
the wall etc. when removing the attachment.
When using the extension wand with
lock function
To install the extension wand, insert it to the suction
inlet of the cleaner until it clicks. Make sure that the
extension wand is locked.
► Fig.20: 1. Suction inlet 2. Extension wand 3. Hook
NOTE: When installing the extension wand, be
sure to align the release button with the hook
on the extension wand. If they are not aligned, the
wand will not be locked and may come off from the
cleaner.
NOTE: When installing the extension wand with-
out lock function (optional accessory), twist and
insert it to the suction inlet of the cleaner in direc-
tion of the arrow. To disconnect, twist and remove it
also in direction of the arrow.
► Fig.21
To remove, pull the extension wand while pushing the
release button.
► Fig.22: 1. Release button 2. Extension wand
When using the nozzle
CAUTION:
To connect the nozzle, twist and
insert it in direction of the arrow to secure the
connection during use. To disconnect the attach-
ment, twist and extract it also in direction of the
arrow. If the nozzle is twisted in the opposite direc-
tion, the capsule may become loose.
To install the nozzle, twist and insert it securely to the
suction inlet of the cleaner or the end of extension
wand. To disconnect, twist and remove it.