Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman DVM851 Bedienungsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für DVM851:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 54
9.2 DC CURRENT
Do not measure current in circuits with voltages > 600V
Range
200µA
2mA
20mA
200mA
10A
Overload protection by fuse: 200mA range F 500mA/600V, 10A range
F10A/600V.
9.3 AC VOLTAGE
Do not measure circuits that may contain voltages > 600V
Range
200V
600V
Frequency range: 40Hz to 400Hz.
9.4 DIODE & CONTINUITY
Do not conduct diode- or continuity measurements on live
circuits.
Range
If continuity exists (less than 60), built-in buzzer will sound
9.5 RESISTANCE
Do not conduct resistance measurements on live circuits.
Range
200
2k
20k
200k
2M
Maximum open circuit voltage: 3.2V
V. 03 – 23/10/2015
Resolution
0.1µA
1µA
10µA
100µA
10mA
Resolution
100mV
1V
Displays the diode's approx. forward voltage drop
Resolution
0.1
1
10
100
1k
DVM851
1% of rdg  2 digits
1.5% of rdg  2 digits
3% of rdg  2 digits
1.2% of rdg  10 digits
Description
0.8% of rdg  2 digits
1.0% of rdg  2 digits
10
Accuracy
Accuracy
Accuracy
©Velleman nv

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis