The emergency stop switch can only effect the stop of all components if these components are electronically
connected with the emergency stop switch. Be sure to test the functionality of the emergency switch before
using the machine. The switch has to be capable of stopping the entire machine in case of an emergency!
Release one of the clamps of the emergency stop
switch wires. Now attach this cable to the GND ter-
minal on the tool changer board (1).
Connect the V1 wires to the V1 terminal on the tool
changer board (1).
Pay attention to the polarity!
Connect the V2 wires to the V2 terminal on the tool
changer board (1).
Pay attention to the polarity!
The cable of the Tool Length Sensor has to be connected to the correct position at the mainboard of your
NOTICE
STEPCRAFT CNC system or, with soldered on jack plug, inserted into the designated jack socket. The use of
wrong cable clamps on the mainboard can result in errors on the control board.
Check your machine control board for a two-pole connection between the
two jack sockets (labeled WLZ). Proceed with the instructions as follows.