Herunterladen Inhalt Inhalt Diese Seite drucken

WimTec SanTec ECOSAN Montage- Und Bedienungsanleitung Seite 12

Inhaltsverzeichnis

Werbung

F
E
GB
Adjustment continuous flow (2 s – 10 min)
The continuous flow time can be adjusted in normal operation mode at any time:
1x.. 5 s
Reset to pre-adjusted factory settings
Seperate the tap from power supply for min. 3 minutes. (Remove the battery)
Then insert the battery again and push the button at the same time. The tap is adjusted to the factory
settings again now - LED lights for 4 s.
All adjustments, which you made up to now at continuous flow, automatic flushing stop time
and active range, are reset!
Change the battery
If the battery gets empty, the LED starts flashing.
SW 2mm
Open screw with socket wrench
(SW 2) by turning 4 times, turn
electronic unit and take it off.
12
All manuals and user guides at all-guides.com
Operation, Commande, Operación
Push the button on the left side of the tap for 5 s - LED lights for 2
seconds then and water flow stops.
If you put your finger from the button within these 2 seconds, the
water flow will be released and setting time for continuous flow
starts to count - so the continuous flow can be adjusted individually:
push the button again after desired time (f.ex. after 20 s) and the con-
tinuous flow is adjusted for this time from now on (new continuous
flow time is f.ex. 20 s). If you don´t push the button again, the water
flows for the maximum continuous flow time of 10 min and the new
adjusted continuous flow time is 10 min.
Remove the battery.
Insert the new battery and
mount electronic unit again.