Travel curve
Speed
OPEN
Acceleration
Cutter
ramp OPEN
distance
OPEN
Cutter speed
OPEN
Cutter speed
CLOSE
Cutter
distance
Brake ramp
CLOSE
CLOSE
Speed
CLOSE
Figure 7-1
Travel curve
Reversing ramp OPEN_CLOSE = direction of travel reverses from
direction of travel reverses from
When reversing from the open to the close direction, the door is braked with the reversing ramp OPEN_CLOSE, and starts
the closing movement with the acceleration ramp CLOSE.
WARNING
After the elevator door has been commissioned, the energies and forces on the heaviest door in the entire elevator system
must be checked by the service personnel, and adjusted if they exceed their limiting values.
The speed limit curve is the characteristic curve which defines the maximum permissible door speed Vmax as a function of
the total door panel weight. According to EN 81, the maximum kinetic energy of the door in the closing direction must not
exceed 10 joules.
If the reversing device is switched off, the maximum kinetic energy must not exceed 4 joules.
Gearing up or down is not allowed on the toothed belts because this would change the kinetic energies or static forces on
the door.
The door width is then no longer valid.
Elevator door drive AT40
A2B00095270A-03, 01/2012
Reverse ramp
V
OPEN
max
Reverse ramp
CLOSE_OPEN
CLOSE
OPEN
to
.
Brake ramp
OPEN
Creep speed
OPEN
Creep speed
CLOSE
V
CLOSE
max
Acceleration ramp
CLOSE
OPEN
CLOSE
to
. Reversing ramp CLOSE_OPEN =
Creep distance
OPEN
Route
Creep distance
CLOSE