6. Connect the switch mode power supply output to X3.
7. The learn run starts automatically, and the learn run button can be released. The 7-segment display (H401) shows "H.".
During the learn run, the door is opened about 10 cm, and closed once or twice at creep speed. The friction of the door
system is then determined by opening and closing the door once through a range of 25 cm at creep speed. The door
then opens and closes through its complete range of movement at reduced speed. After the door has opened about 10
cm, it passes through a short acceleration ramp to determine the weight of the door. In the CLOSED position, the door
parameters and the determined door width are saved. The decimal point in the 7-segment display (H401) flashes during
the save process. The 7-segment display (H401) shows "u" when saving has finished.
8. The door can now be opened with the OPEN button S402. The 7-segment display (H401) shows "o" while the door is
opening.
9. Switch off the controller by pulling out the power plug or the X3 plug.
10. Connect the control signals to the X6 connector as shown in the terminal circuit diagram (see Terminal circuit diagram of
control inputs (Page 43)).
11. Connect the light barrier to X6 (see Auto-Hotspot or text on cover). If the light barrier input (input 1) is not used, X6 must
be wired to X4 as indicated by the lines in the layout diagram. The sensor must be connected here if the DCPS function
is used.
12. Plug in terminal connectors X6 and X4.
13. Switch on the controller (plug in the power plug or the X3 plug). The four LEDs alongside the plug connector X3 indicate
which control signal is currently active. If there is no obstruction in the range of movement of the door, the LED for the
light barrier should be lit continuously.
14. If the control signal CLOSE is present, the door moves into the CLOSED position at initial speed. If an OPEN control
signal is present, the door moves into the OPEN position at initial speed.
15. Once the controller has detected the door OPEN and CLOSED end positions, the subsequent opening and closing
movements proceed at normal speed once again.
16. The door travel values can be matched to the individual door for specific applications with the aid of the integrated
terminal module or the Service Tool (optional). Parameters can also be changed with the aid of the Sidoor User Software
(optional, part of the Sidoor Software Kit). Its operation is described in the Appendix to these instructions. Simple settings
can also be made with the three buttons and the 7-segment display on the basic unit via the Electrical adjustment with
the minimal editor (Page 37).