Herunterladen Inhalt Inhalt Diese Seite drucken

Klauke SSG65 Bedienungs- Und Wartungsanleitung Seite 25

Sischerheitschneidgerate
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Instruction Manual SSG
_________________________________________________________________________________________________________________
The hydraulic oil has to be completely changed after two years. The oil change must be
done by the manufacturer. Changing the oil must be documented.
Attention
Hydraulic oils can cause cutaneous eruption (eczema) or other health
hazards. Avoid long contact with the skin. Wash hands carefully after every
contact.
Attention
Spilled hydraulic oil must be absorbed immediately.
5.6. Reference as to which (spare-) parts can be exchanged by the customers
Within the determined use of the unit the customer is only allowed to change the blades
(Pos.-No. 12).
Attention
Do not destroy the seals of the unit!
Do not attempt to repair the tool yourself, and do not remove any parts such as screws and
other components.
5.7. Storage and transport of the unit
To avoid damaging the unit during transport it should always be transported in a carrying
case. It must be paid attention that the insulating hose (Pos.-No. 9) is properly rolled up
avoiding an extreme bending radius (min. 38 mm).
6. Troubleshooting
The hydraulic safety cutting unit is basically trouble-free. Should nevertheless be trouble
with this unit return it to the manufacturer or contact the manufacturer for advice.
Below there is a list of possible errors and their remedy:
The cutting cycle can not be terminated properly.
=> Inform the net provider, respectively the control office, immediately. In case it must be
assumed that the blades have already cut into the cable special caution is required.
Immediate action is required to cordon the working site to avoid immediate hazards for
nearby personnel.
The cable must be checked with suitable measuring equipment by an electrician to
determine the voltage status. Only when the voltage-free state of the cable is definitely
determined the cutting head can be approached.
The cutting head (Pos.-No. 11) is damaged during the cutting cycle.
=> In case the cutting cycle could be completed despite of the damage the cutting head
must be returned to the manufacturer for a damage report and repair.
Insulating fluid is leaking.
=> Stop cutting cycle, actuate the retract lever (Pos.-No. 6) and examine the safety cutting
unit for leakage's. If the leakage can not be positively located the complete unit must be
returned to the manufacturer for service.
All manuals and user guides at all-guides.com
page 25

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ssgg85Ssg105Ssgg105Ssg120/3

Inhaltsverzeichnis