5
°C / °F
To set the desired temperature unit, press and hold the „MODE"
button for 2 seconds until the corresponding symbol appears
on the display.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Store the device in a clean
and dry place.
Technical data
Humidity (relative)
Measuring range
Accuracy (absolute)
Ambient temperature
Measuring range
Accuracy
Dew point temperature
Measuring range
Accuracy
Power supply
Operating conditions
Storage conditions
Dimensions (W x H x D)
Weight
Subject to technical changes without notice. 19W20
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=ABD
20% ... 90%
± 5% rH (25% rH ... 85%rH)
-10°C ... 50°C
1°C
-28,6°C ... 47,9°C
± 2 °C
1 x 1,5V LR44 (AG13)
-10°C ... 50°C, max. humidity 99% rH,
no condensation, max. working
altitude 2000 m above sea level
-10°C ... 60°C, max. humidity. 85% rH
138 x 27 x 19 mm
38 g (incl. battery)