1

Troubleshooting

EN
4
Troubleshooting
Fault
The green Power LED does not
light up when the power supply
is connected
The red Charge LED does not
light up when the battery is
plugged in
5
Servicing
 To ensure proper charger function, keep the contacts of the charger and batteries free of dirt.
6
Service
7

Technical data

Features
Supply voltage
Power supply frequency
Rated battery voltage
End-of-charge voltage
Idle voltage
Charging current
Degree of protection DIN EN 60529 (IEC 60529)
Protection class DIN EN61140 (VDE0140-1)
Weight without cable
Operation temperature
Operation, relative humidity
Storage temperature
6
Cause
No power supply voltage
Power cable defective
Charger defective
The battery that is plugged in has
already been charged (red LED
stays off).
The battery contacts are not con-
nected correctly
Contacts are dirty
Battery may be faulty
Caution
 To clean the charger, make sure the power plug is disconnected and clean with a dry
cloth.
 Do not use easily inflammable substances for cleaning.
If repair is required, send the complete charger to Sales & Service Center. It may only be
repaired by authorized technicians. Opening the charger will void the warranty.
P1893BA | 2019-01
Measure
 Check and restore the
power supply voltage.
 Replace power cable.
 Replace charger.
 Check battery for proper
function.
 Plug the battery in again.
 Clean the contacts of the
charger and battery.
 Check battery and replace if
necessary.
Data
100 ... 240 VAC
47 ... 64 Hz
26 VDC
29.4 VDC ±1%
Max. 34 VDC
Max. 2000 mA ±10%
IP30
II
0.7 kg
+0 to +40 °C (+32 to +104 °F)
0...90%, non-condensing
-20 to +60 °C (-4 to +140 °F)
Apex Tool Group GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis