1
Troubleshooting
EN
4
Troubleshooting
Fault
The green Power LED does not
light up when the power supply
is connected
The red Charge LED does not
light up when the battery is
plugged in
5
Servicing
To ensure proper charger function, keep the contacts of the charger and batteries free of dirt.
6
Service
7
Technical data
Features
Supply voltage
Power supply frequency
Rated battery voltage
End-of-charge voltage
Idle voltage
Charging current
Degree of protection DIN EN 60529 (IEC 60529)
Protection class DIN EN61140 (VDE0140-1)
Weight without cable
Operation temperature
Operation, relative humidity
Storage temperature
6
Cause
No power supply voltage
Power cable defective
Charger defective
The battery that is plugged in has
already been charged (red LED
stays off).
The battery contacts are not con-
nected correctly
Contacts are dirty
Battery may be faulty
Caution
To clean the charger, make sure the power plug is disconnected and clean with a dry
cloth.
Do not use easily inflammable substances for cleaning.
If repair is required, send the complete charger to Sales & Service Center. It may only be
repaired by authorized technicians. Opening the charger will void the warranty.
P1893BA | 2019-01
Measure
Check and restore the
power supply voltage.
Replace power cable.
Replace charger.
Check battery for proper
function.
Plug the battery in again.
Clean the contacts of the
charger and battery.
Check battery and replace if
necessary.
Data
100 ... 240 VAC
47 ... 64 Hz
26 VDC
29.4 VDC ±1%
Max. 34 VDC
Max. 2000 mA ±10%
IP30
II
0.7 kg
+0 to +40 °C (+32 to +104 °F)
0...90%, non-condensing
-20 to +60 °C (-4 to +140 °F)
Apex Tool Group GmbH