Herunterladen Inhalt Inhalt Diese Seite drucken

Qlima PGF 1211 Gebrauchsanweisung Seite 69

Vorschau ausblenden Andere Handbücher für PGF 1211:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
- Ø 8-12 mm hose (all EU countries except France)
- G1/2'' (France only)
For gas hose with threaded connectors: bind 2 or more rounds of plumbing tape
around the gas pipe before connecting the gas hose for security.
Bind 2 or more rounds of Teflon plumbing tape around the gas burner inlet con-
nector and connect the gas pipe. Use a wrench to tighten the connection.
Connect the other end of your gas hose according to the mounting instruction as
supplied with the gas hose and/or supplied with the gas regulator.
Note:
-
The gas hose is NOT included with the heater
-
The gas regulator is not included with the heater
Connect the regulator to the gas cylinder (not included) according to the
mounting instruction as supplied together with the gas regulator and/or the gas
cilinder
Put gas cylinder on the base.
WARNING! Ensure the hose does not contact any high temperature surfaces, or it
may melt and leak causing a fire. After the cylinder is placed inside the heater, secure
the cylinder with block belt tightly.
LIGHTING INSTRUCTION
Check and ensure that an AA battery is inside the ignition chamber. Use a new
battery so you are sure the battery is full of power.
Ensure that the '+' side of the battery is facing outside (so '+' faces towards the
user)
TO TURN ON THE HEATER
Check that the regulator seal is correctly fitted and able to fulfil its function.
a)
Depress and turn control knob clockwise to OFF position.
b)
Fully open gas valve (positioned at gas bottle or regulator).
c)
Depress control knob and turn knob counter-clockwise to PILOT position.
d)
Keep pressing down the variable control knob and hold for 30 seconds. While
holdinng down the variable control knob: press the button marked with
"IGNITION" several times until the pilot flame ignites.
e)
With the pilot light is lit, keep control knob depressed for 60 seconds.
Note:
1.
If a new tank has just been connected, please allow at least one minute or more
for the air in the gas pipeline to purge out through the pilot hole,
2.
If the pilot light has not ignited, turn heater control knob to OFF position, fully
close gas valve, wait 5 minutes, then repeat steps b–e of the Lighting Instructions.
3.
If the pilot light ignites but does not stay lit, turn heater control knob to OFF
position, fully close propane gas valve, wait 5 minutes, then repeat steps b-c-d-e.
f)
After depressing the control knob for 60 seconds, turn control knob to LOW. To
increase the temperature, turn towards HIGH.
4
69

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis