- minimum 100 cm top clearance
- minimum 100 cm side clearance
- Heater must only be placed and used on a firm, level and stable underground.
WARNINGS
Never use the heater while it is raining, the glass tube would break when it sud-
denly met water.
Always turn off the heater while there is a rain.
Never splash any liquid to the glass tube when the heater is working.
The glass tube will be extremely hot when it is working, never try to touch it
and keep the children away from the heater.
Always ensure the heater stands firmly, the glass tube may break if the heater
was fell down onto ground.
Never use the heater if the glass tube has any crack.
GAS REQUIREMENTS
Use propane, butane or LGP only. See rating label on the appliance.
Maximum size of cylinder suitable for the appliance is Ø 32 cm x 59 cm (high).
Gas supply to the appliance from the gas cylinder: the appliance requires
approved gas hose in 60-80 cm length and a gas regulator. The hose and regula-
tor assembly must conform to local standard codes.
Regulator maximum inlet pressure must not exceed 690 kPa.
Regulator outlet pressure to be 28 mbar (2.8 kPa) to 37 mbar (3.7 kPa) depend-
ing on countries.
The installation must conform to local codes, or in the absence of local codes, to
the standard for the storage and handling of liquid petroleum gases.
A dented, rusted or damaged gas cylinder may be hazardous and should be
checked by an authorized dedicated gas specialist.
Never use a gas cylinder with a damaged valve connection.
The gas cylinder must be arranged to provide for vapor withdrawal from the
operating cylinder.
Never twist the flexible tubes and hoses.
Disconnect the gas cylinder when the heater is not use.
Do not connect the gas cylinder directly to the appliance without regulator
Use only the type of gas and the type of cylinder specified in these instructions
LEAK TESTING
Gas connections on the heater are leak tested at the factory prior to shipment.
A complete gas tightness check must be performed at the installation site due
to possible mishandling in shipment and/or installation or because of excessive
pressure being applied to the heater. The heater must be checked with a full
cylinder.
1. Make sure the safety control valve is in the OFF position.
2. Make a soapy water solution of one part liquid detergent and one part water.
The soapy water solution can be applied with a spray bottle, brush or rag to all
gas connections. Soap bubbles will appear in case of a Ieak.
WARNING: Never leak test while smoking!
WARNING: In the event of gas leakage, the appliance shall not be used or if
alight, the gas supply shall be shut off and the appliance shall be investigated
and rectified before it is used again.