Operation

Use the control keys to:
Keys
Description
turn the nebulizer on/off;
activate the SETTING mode of the nebulizer;
set the frequency of the cycles;
set the duration of the cycles;
start spraying, saving the duration and frequency selections.
1.
Press the start button
to turn on the nebulizer.
The nebulizer is now in STANDBY mode and the LED is lit red;
2.
Use the
and
keys to select and set the frequency or duration of the cycles;
3.
Press the
key: the nebulizer is now in SETTING mode. The frequency or duration value
will flash for 8 seconds; after 8 seconds the nebulizer will return to STANDBY mode and
save the selected value;
4.
Within the 8 seconds mentioned above, start to select the desired value using
the keys
and
:
A. Pressing the
or
key will display the values one after the other, in ascending or
descending order;
B. Press and hold the
or
faster and continuously;
64
Art. 410 / Art. 411
Geyser Nebulizer 4 L and 12 L Li-Ion
Assembly and use
key makes the display show the selectable values
Art. 410 / Art. 411
Geyser Nebulizer 4 L and 12 L Li-Ion
Assembly and use
5.
After selecting a value:
A. press the Play key
to save the selection and go directly to
the next selection (duration or interval);
key to exit without saving and return directly to SETTING mode for
B. press the
the next selection (duration or interval);
6.
The value to be selected will flash for 8 seconds: within this time, use the
start selection:
A. press the Play key
to save the selection;
B. press the
key to exit without saving and return directly to the SETTING mode
for the next selection (duration or interval);
Press the Play key
7.
to start spraying. The spraying starts after 30 seconds to ensure
the safety of the operator, who has time to move away from the device. During these 30
seconds the LED lights up green and flashes and the nebulizer emits repeated beeps.
8.
Once the operation has been carried out for the set duration, the nebulizer returns to
STANDBY mode and will automatically start after the selected time interval has elapsed.
The nebulizer prevents starting of a new cycle when the battery charge level is less than
25% (one bar). Recharge the battery.
If the tank is empty, the nebulizer returns to STANDBY mode with the red LED and
flashing.
The current selection is saved every time the nebulizer is turned off. This means that, after
turning the nebulizer on again, the user can simply press the Play key
using the same settings as before for spraying.
It is not possible to program the start of spraying after a certain time interval. Time intervals
apply only to cycles after the first one, which starts 30 seconds after the Play key
pressed.
For further information about the product, please contact info@stockergarden.com.